Short answer
A stair calculation starts by dividing the floor-to-floor height into equal risers: number of risers = floor-to-floor height ÷ target riser height (rounded to a whole number so that the riser stays within 15–18 cm). The tread depth is found with the comfort formula 2r + g ≈ 60–64 cm. For example, if a 300 cm floor-to-floor height is divided into 17 risers, the riser is 17.6 cm and the tread 26–28 cm. On the plan, you draw the stair with the rectangle and array commands and show the direction of travel with an arrow.
Basic terms
| Term | Meaning |
|---|---|
| Riser (r) | The vertical height between two steps |
| Tread / going (g) | The horizontal depth of the surface you step on |
| Flight | The steps between two landings |
| Landing | The level resting area between flights |
| Stair width | The clear width of the flight |
Calculation step by step
01Take the floor-to-floor height
Measure the height from finished floor to finished floor. Example: 300 cm.
02Find the number of risers
Choose a target riser (e.g. 17.5 cm) and divide: 300 ÷ 17.5 = 17.1 → 17 risers.
03Calculate the actual riser
300 ÷ 17 = 17.65 cm. All risers must be equal.
04Find the tread
If 2r + g = 63 cm, then g = 63 − 2 × 17.65 = 27.7 cm → 28 cm.
05Calculate the flight length
The number of treads is one fewer than the number of risers: 16 × 28 = 448 cm. If it does not fit in a single flight, consider two flights with a landing (e.g. 8 + 8 treads).
| Floor-to-floor height | Number of risers | Riser (cm) | Tread (2r + g = 63) |
|---|---|---|---|
| 270 cm | 16 | 16.9 | 29 cm |
| 280 cm | 16 | 17.5 | 28 cm |
| 300 cm | 17 | 17.6 | 28 cm |
| 320 cm | 18 | 17.8 | 27 cm |
This calculation is a preliminary sizing based on the comfort formula. For residential, shared-use and escape stairs, the maximum riser, minimum tread and stair width are set separately in zoning and fire regulations; use the regulations in force for your project.
Drawing the stair on the plan
01Draw the flight
Draw the outline of the flight with
RECTANG:RECTANG 0,0 4480,1200(448 cm × 120 cm).02Array the tread lines
Draw the first tread line with
LINE 280,0 280,1200and multiply it withARRAY:ARRAY 1 15 280 0(1 row, 15 columns, 280 mm spacing).03Show the direction of travel
Add a polyline (PLINE) and an arrow along the middle of the flight to show the direction of travel, and the text "UP" at the start.
04Add the break line
On a floor plan, the stair is cut by an angled break line at roughly the cutting-plane height (usually around 1 m); show the treads above the line as dashed (
LINETYPE DASHED).05Add dimensions
Write the flight width and the number and size of the steps: "17 × 17.65 / 28".
Frequently asked questions
The most common comfort formula is 2r + g ≈ 60–64 cm, where r is the riser height and g the going (tread depth). For a 17.5 cm riser, the tread is about 28 cm.
With a target riser of 17.5 cm, 17 risers are needed (300 ÷ 17 = 17.65 cm). The number of treads is one fewer than the number of risers: 16 treads.
For comfort, 15–18 cm is common. Maximum values by building type are set in zoning and fire regulations; check the regulations in force for your project.