Short answer
On a floor plan, dimensions are given in three strings from the outside in: the overall dimension outermost, grid dimensions in the middle, and wall and opening dimensions innermost; internal room dimensions and levels are written inside the plan. In ARCTE CAD, horizontal and vertical dimensions are given with `DIMLINEAR` and angled edges with `DIMALIGNED`. Dimensions are linked to the points they measure: when the geometry changes, out-of-date dimensions are flagged and no output is produced until they are fixed.
Dimension layout on a plan
| String | What it shows | Where |
|---|---|---|
| 1. Overall (outermost) | The building's overall length and width | Outside the plan, furthest away |
| 2. Grid | Distances between grid lines | Inside the overall dimension |
| 3. Detail | Wall thicknesses, window and door openings, wall segments | The string closest to the plan |
| Internal dimensions | Internal width and depth of the space, internal wall thicknesses | Inside the spaces |
| Levels | Floor levels (relative to the ±0.00 datum) | In each space and at entrances |
The total of each string must agree with the string above it: the detail dimensions must add up to the grid dimension, and the grid dimensions to the overall dimension. This check catches drawing errors before they reach the sheet.
Place the strings at equal spacing from the plan (e.g. 8–10 mm on paper on a 1:50 sheet). For scale and text size, see the scale guide.
Dimensioning step by step
01Set the precision
Choose the number display precision with
UNITS(0–9 decimal places). On a plan drawn in millimetres, dimensions are usually shown without decimals.02Turn on snapping
Turn on object snap (F3) so that dimension endpoints attach to the correct point; make sure endpoint and intersection snaps are selected.
03Horizontal and vertical dimensions
DIMLINEAR(Turkish alias:ölçü) gives a dimension from two endpoints and an offset:DIMLINEAR 0,0 5000,0 1200 H. You can choose the direction as H (horizontal), V (vertical) or A (automatic).04Angled edges
For the true length of angled walls, use
DIMALIGNED(Turkish alias:hizalı ölçü):DIMALIGNED 0,0 3000,4000 500.05Align the string
Give the dimensions in a string the same offset; object tracking (F11) makes it easier to keep the dimension lines aligned.
06Check
After the plan changes,
RELATIONSlists the dimensions that need updating. Relink a dimension whose link is broken withRELINK, or delete it and dimension again.
In ARCTE CAD, dimensions are individual dimensions that you give one by one; there is no continuous dimension string (DIMCONTINUE) and no dimension style command. The dimension line is shown with a 45° oblique tick, as is customary in architectural drawings.
Associative dimensions: what happens when the plan changes?
| Situation | What you see | What to do |
|---|---|---|
| You moved a wall | The dimension follows the endpoints it is linked to | Check the new value |
| You trimmed or broke a wall and the link is ambiguous | The prefix "LINK BROKEN" in the dimension text; the old points are kept | Relink with RELINK or dimension again |
| Output while a dimension is out of date | "Output stopped: there is an out-of-date dimension/area" | Fix the dimensions in the RELATIONS list; the project can still be saved as .arc |
| Linked dimension on a locked or hidden layer | The wall is not changed; the message shows the dimension | Turn on or unlock the dimension's layer |
Frequently asked questions
Usually three outer strings are given: the overall dimension outermost, grid dimensions in the middle, and wall and opening dimensions innermost. Internal room dimensions and levels are written inside the plan.
The wall was trimmed or broken, and it became ambiguous which part the dimension should link to. The old points are kept; relink the dimension with RELINK or delete it and create it again.
A dimension that has not been updated after the geometry changed leads to a wrong sheet. Once you fix the dimensions listed by RELATIONS, the output is produced.
No. Each dimension is given separately with DIMLINEAR or DIMALIGNED; by using the same offset you can keep the string aligned.